Fluke 17B+ Digital Multimeter

(1 customer review)

  • Simple to use and large LCD display along with many other user friendly benefits makes the 17B DMM a true companion, no doubt they have become first choice of today’s maintenance and field engineers.
  • Display LCD Display, Counts 4000
  • AC Voltage Range 400mV to 1000V
  • AC Voltage Accuracy 1.0% 3
  • DC Voltage Range 400mV-1000V
  • DC Voltage Accuracy 0.5% 3
  • AC Current Range 400A – 10 A
  • AC Current Accuracy 1.5% 3 Digit
  • DC Current Accuracy 1.5% 3 Digit
  • DC Current Range (Amp) 400A – 10 A
  • Resistance Range (Ohm) 0-40 M
  • Resistance Accuracy 1.5% 3 Digit
  • Capacitance Range (F) 40nF – 1000 F
  • Capacitance Accuracy 5% 5 digit
  • Frequency Range (Hz) 50Hz – 100 kHz
  • Frequency Accuracy 0.1 % 3
  • Operating Temperature 0 to 40C
  • Storage Temperature -30 to 60Altitude 2000 m (Operating), 12,000 m (Storage)
  • Power Input NEDA 24A, IEC LR03 AAA x 2 Batteries
  • Standard Accessories Cases and Holsters , Test Leads
  • Dimensions 183x91x49.5 mm
  • Weight (g) 455 g

11,200.00

Compare

Fluke 17B+ is an accurate, reliable and rugged digital multimeter. This 1000 V Digital Multimeter measures both frequency and temperature. It can also be used to measure resistance, voltage, capacitance and continuity. It warns in case of overvoltage before you initiate. It can be even used for a diode test and data hold. This electrical power testing tool comes with a 50 Percent large and bright display. This multimeter is super lightweight and can be easily used in a single hand

Category:
Weight .5 kg

 Fluke 17B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
Frequency1 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1% + 3
Duty Cycle1 1% to 99% 0.1% 1% typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Temperature 50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C 2% ±1 °C
±2 °C
9% ±2 °C
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only

Based on 1 review

5.0 overall
1
0
0
0
0

Add a review